Veterinary MRI Systems
Esaote G.Scan rotating Veterinary MRI scanner
Esaote logo

G-scan Equine

Innovative. Illuminate. Initiate.

While many MRI systems are capable to scan the limbs of horses from the carpus and tarsus distally, because sufficiently easy to drag the anatomy to the isocenter of the magnet, when it comes to stifle joint, it gets impossible for every MRI in the market for the sole exception of the Esaote G-scan equine. In fact, thanks to its revolutionary system design and rotating mechanism, it enables a unique patient positioning, which is functional to an optimal investigation of the stifle joint, moreover peculiarities of the system are now looming new horizons on the future possibility to scan the horse under sedation.

We offer both new and refurbished systems

Key Features:

  • Easy positioning: Correct positioning of the district of interest in the magnet is key to obtain a good image quality. G-scan equine has some particular features that substantially facilitates the work of the MRI tech making for a faster scan and better image quality.
  • Real-Time Gantry Monitor: The small monitor situated on magnet displays in real time the MRI image for an immediate set up.
  • Dedicated coils that can be opened to facilitate positioning of the horse’s limb.
  • Versatility, suitable also for small animal applications. The G-scan Equine can also be equipped with the appropriate software and coils dedicated to small animal applications to enhance the patient database.

General installation:

  • Minimum space requirements: 55 m² (592 sq.ft.)
  • Height minimum: 2.4 mt
  • Environmental requirements: 21-24 °C ± 3 °C/Std.
  • Floor loading: 8000 Kg
  • MRI compatible horse table by 3rd party supplier

ESAOTE VETERINARY MRI

G-scan Equine

The Esaote G-scan Equine sets a new standard in equine diagnostics, engineered specifically to tackle the complexities of equine MRI scanning with a proprietary rotating magnet that tilts from 0° to 90°. It is the only MRI system in the world capable of imaging the equine stifle joint, while also covering the full range of distal limb anatomy from the carpus and tarsus distally. Developed in close collaboration with veterinary experts, with tailored animal-centric sequences, dedicated exam protocols, and a vet-specific user interface, the G-scan Equine unlocks a new standard of equine diagnostic confidence.

EQUINE MRI, ROTATING MAGNET, STIFLE IMAGING, 0-90° TILT, STANDING SEDATION, 7RF COILS

Esaote G.Scan rotating Veterinary MRI scanner

MAGNET DESIGN

Rotating

RUNNING COSTS

<2 kW

RF COILS

7

UNIQUE FEATURING

Stifle Imaging

INTERFACE

Dedicated Vet UI

TECHNICAL SPECIFICATIONS

System Specifications

System

Magnet design

Proprietary rotating magnet, 0° to 90° tilt range

Power consumption

Less than 2 kW

Cryogenic liquids

Not required

Species

Equine, a dedicated system for horses

Exam regions

Stifle joint, carpus, tarsus, fetlock, pastern, hoof, neuroimaging

Unique capability

Only MRI system worldwide capable of imaging the equine stifle joint

Positioning principle

Rotating magnet angles to horse, horse stands in natural position

Stifle joint access

The rotating mechanism enables unique patient positioning for stifle investigation

Sedation requirements

System designed for standing sedation, future potential for sedated scanning

Software integration

Vet-specific language and image orientation built into interface

Protocol design

Developed in collaboration with veterinary experts, tailored animal-centric sequences

Total coils available

7 dedicated equine RF coils

Linear spine coil

Head, spine, medium breeds, and horse extremities

Linear multipurpose flex coil

Multipurpose flexible coil

DPA head coil

Head, spine, medium breeds, and horse extremities

DPA spine coil

Spine, large breeds

DPA small parts coil

Head, small breeds, and extremities

Power requirements

Less than 2 kW, standard power supply sufficient

Siting

Designed to fit in equine facility environments

CLINICAL APPLICATIONS

What this system is built for

The G-scan Equine is purpose-built for equine veterinary facilities that require MRI coverage of the full distal limb, including the stifle joint, which no other MRI system in the world can access, delivering diagnostic capability that changes what is possible in equine orthopedic practice.

Stifle joint imaging

The rotating magnet mechanism enables unique patient positioning that makes the G-scan Equine the only MRI system worldwide capable of imaging the equine stifle joint, opening definitive soft tissue diagnosis of meniscal, ligamentous, and articular cartilage pathology previously inaccessible to MRI.

Distal limb orthopedic imaging

From the carpus and tarsus distally, covering the fetlock, pastern, coffin joint, collateral ligaments, and hoof, the G-scan Equine delivers high-resolution MRI of the equine distal limb with dedicated protocols developed specifically for equine anatomy and lameness diagnosis.

Equine neuroimaging

Dedicated neurological imaging protocols for the equine cervical spine and cranium extend the G-scan’s clinical utility beyond orthopedics, enabling MRI-based diagnosis of cervical stenosis, wobbler syndrome, and intracranial pathology in horses.

Standing sedation workflow

The system is designed for equine facilities using standing sedation; the horse remains in a natural weight-bearing position while the rotating magnet angles to the required imaging plane, minimizing anesthesia risk and simplifying the examination workflow for horses and staff alike.

RELATED SYSTEMS

Other Esaote MRI systems

ESAOTE

Magnifico Vet

Advanced spectral CT with AI-powered reconstruction for superior material differentiation.

ESAOTE

Vet MR-Grande

Advanced spectral CT with AI-powered reconstruction for superior material differentiation.

ESAOTE

O-scan VET

Whole-organ CT with advanced detector technology and dynamic scanning capability.

GET STARTED