SIEMENS VETERINARY CT
SOMATOM go.Top
The Siemens SOMATOM go.Top brings full-featured 64-slice CT capability to veterinary practice within the intuitive, tablet-based go. platform ecosystem. With 0.33-second rotation speed, a 75 kW generator, TwinBeam Dual Energy, advanced cardiac imaging, and the 175 mm/second scan speed optimized for trauma workflows — all within a compact one-room footprint, it delivers high-end CT performance without high-end complexity.
64-SLICE, DUAL-ENERGY, CARDIAC CT, .33 SEC ROTATION, 75 KW GENERATOR, TRAUMA OPTIMIZED
ACQUIRED SLICES
64/128
Z-COVERAGE
64 x .6 mm
ROTATION SPEED
.33 sec
GENERATOR
75 kW
GANTRY BORE
70 cm
TECHNICAL SPECIFICATIONS
System Specifications
Detector
Acquired slices
64 (128 IVR option)
Reconstructed slices
Up to 384
z-Coverage
64 x .6 mm
Detector technology
Stellar; high contrast, high resolution
Acquisition speed
Up to 175 mm/sec, optimized for trauma
X-Ray System
X-ray tube
Athlon, 7 MHU; up to 825 mA at low kV
Generator power
75 kW
Max mA
625 mA (825 mA with option)
kV selection
70, 80, 90, 100, 110, 120, 130, 140 kV
Rotation speed
Up to .33 sec
Imaging
Dual energy
TwinBeam Dual Energy, zero-click inline results
Dose reduction
SAFIRE iterative reconstruction (up to 60%); CARE kV/Dose
Metal artifact reduction
iMAR; iterative metal artifact reduction
Intervention guidance
Guide & Go: tablet-based CT-guided intervention
Cardiac imaging
Supported: cardiac CTA and dynamic applications
Table & Install
Table load
Up to 307 kg
Gantry bore
70 cm
Workflow
myExam Companion AI guidance; tablet-based mobile workflow
Positioning
FAST 3D Camera, gantry mounted
Footprint
4 sqm; one-room concept
Availability
New and remanufactured units
CLINICAL APPLICATIONS
What this system is built for
The SOMATOM go.Top is built for veterinary practices managing a full spectrum of clinical CT demand, from routine daily studies and dual-energy acquisitions through to cardiac CTA, trauma surveys, and CT-guided intervention.
Cardiac imaging
64-slice acquisition with 0.33-second rotation and advanced cardiac reconstruction enables definitive cardiac CTA and functional studies in companion animals, resolving coronary and structural detail even at elevated heart rates.
Dual-energy & spectral imaging
TwinBeam Dual Energy delivers zero-click inline spectral results including virtual non-contrast images, iodine quantification, and material decomposition from every contrast acquisition, adding diagnostic value without additional scan time.
Trauma & emergency CT
175 mm/second maximum scan speed enables rapid whole-body trauma surveys for critically injured patients under anesthesia, minimizing scan time and anesthesia duration when speed is the clinical priority.
CT-guided intervention
Guide&Go tablet-based guidance and iMAR metal artifact reduction make the go.Top a capable interventional CT platform for biopsy, drainage, and advanced procedures across a range of companion animal and exotic species cases.
RELATED SYSTEMS
Other Siemens CT systems
SIEMENS
SOMATOM go.Now
Advanced spectral CT with AI-powered reconstruction for superior material differentiation.
SIEMENS
SOMATOM X.cite
Advanced spectral CT with AI-powered reconstruction for superior material differentiation.
SIEMENS
SOMATOM X.ceed
Whole-organ CT with advanced detector technology and dynamic scanning capability.
SIEMENS
NAEOTOM Alpha
Ultra-high resolution CT with submillimeter detail for small animal neurological imaging.