CANON INDUSTRIAL CT
Aquilion ONE / PRISM Edition
The Canon Aquilion ONE / PRISM Edition brings spectral CT capability to industrial imaging, delivering 320-detector row whole-organ coverage, advanced material decomposition, and AiCE Deep Learning Reconstruction in a platform engineered for the most demanding non-destructive testing, research, and materials analysis applications. Whether characterizing complex composite structures, mapping fluid saturation in reservoir core samples, or performing high-throughput quality inspection, the PRISM Edition delivers spectral data and image quality that no conventional industrial CT system can match.
320-SLICE, SPECTRAL CT, MATERIAL DECOMPOSITION, NDT & NDE, PETROPHYSICS, RESEARCH, DEEP LEARNING RECON
Z-AXIS COVERAGE
16 cm
DETECTOR
.5mm x 320
ROTATION SPEED
.275 sec
GENERATOR
100 kW
GANTRY BORE
78 cm
System Specifications
Gantry
Gantry bore
78 cm
Gantry tilt
±30°
Rotation speed
.275 sec
Reconstruction speed
Up to 80 fps
User interface
New User Experience
Detector & Recon
Detector
.5 mm 320 PUREVISION
Z-axis coverage
16 cm
Reconstruction matrix
PIQE 1024
Dose reduction
SilverBeam filter
DLR technology
AiCE Deep Learning Reconstruction
Couch
Couch width
47 cm
Couch height
33 cm
Couch capacity
694 lbs
Workflow assist
3D Landmark Scan, Anatomical Landmark Detection
Installation
Minimum room size
19 m
Generator power
100 kW
Availability
New and pre-owned units
What this system is built for
The Aquilion ONE / PRISM Edition is built for industrial and research institutions that require spectral CT data, exceptional spatial resolution, and whole-volume coverage in a single acquisition, supporting the most technically demanding non-destructive evaluation workflows.
Petrophysics & reservoir analysis
Spectral CT material decomposition enables simultaneous quantification of mineralogy, fluid saturation, and porosity in reservoir core samples, delivering data that conventional CT and laboratory analysis cannot provide in a single scan.
Composite & advanced materials inspection
320-row whole-volume coverage captures complex multi-layer composite structures in a single rotation, while spectral data differentiates materials by atomic number, enabling delamination detection, void mapping, and fiber orientation analysis with unmatched clarity.
Research & university imaging
Universities and national laboratories use the PRISM Edition for advanced materials research, in-situ loading studies, and novel contrast agent development, where spectral CT capability and AiCE reconstruction open experimental possibilities unavailable on any other industrial platform.
High-throughput industrial inspection
A 78 cm bore accommodates large or irregularly shaped industrial components, enabling high-throughput non-destructive inspection of manufactured parts, castings, and assemblies at production-line speeds.
Other Canon CT systems
CANON
Aquilion ONE / GENESIS Edition
320-row CT with 16 cm coverage and AiCE deep learning reconstruction.
CANON
Aquilion Precision
Ultra-high resolution CT that resolves detail as small as 150 microns.
CANON
Aquilion Serve SP
80-row CT with INSTINX workflow automation and AiCE deep learning reconstruction.
Ready to find the right imaging system?
Already own a Canon CT? Ask us whether it qualifies for an upgrade.
